Factory Faults
Poor insertion of tubing into detonator at crimping
Missing components on unit (No cobra clip & no heat seal)
Detonator double crimped at base charge (Safety hazard)
Unidirectional propagation resulting in misfire
Tube burst due to a too high core load
No or low core load failure
Failure to Propagate (HMX/Aluminum ratio)
Detonator not clipped in top position
Detonator clipped on one side of skirt only
Tube damaged in plant
Will most likely burst in use due to weak points along the length of the tube.
Detonator not clipped in properly
Detonator not clipped into 2nd position properly and pulled back.
Damage to Shocktube in use
DAMAGED TUBING (Rough handling)
CLOSE CONNECTING – No RunUp
At least half a meter run-up must be allowed for shock tube
CLOSE CONNECTION
(No run-up allowed) At least half a metre run-up from the donor detonator to acceptor must be allowed for shock tube)
Shrapnel embedded into tubing
Shrapnel damage
Broken Clips
Broken clips resulting from lines being too tight.
Physical Damage
Example of tube strangulation due to physical damage